Framed-type glass curtain wall
Contents |
[edit] Introduction
A framed-type glass curtain wall is a non-structural outer covering of a building where the exterior walls are made of large glass panels set within a metal framework. This type of curtain wall system is designed to protect the interior of the building from the elements (such as wind and rain) while allowing natural light to enter.
[edit] Key Features of a Framed-Type Glass Curtain Wall
Structural Support:
- The primary structural support comes from a metal frame, typically made of aluminium or steel. This frame is attached to the building's structural components, such as floors or columns.
- Large glass panels are inserted into this metal framework. The glass is often double-glazed or laminated for added strength and insulation.
Non-Load Bearing:
- Unlike traditional walls, a framed-type glass curtain wall is non-load bearing. This means it does not carry any of the structural weight of the building. Instead, the weight is supported by the building's frame and foundations.
- Because the curtain wall is separate from the structural framework of the building, it can move independently. This allows it to better withstand forces such as wind pressure and seismic activity without transferring stress to the building’s structure.
Design and Aesthetics:
- Glass curtain walls give buildings a sleek, modern look. They are often used in high-rise buildings and commercial structures for their aesthetic appeal.
- They provide a high degree of transparency, allowing natural light to penetrate deep into the interior spaces, which can reduce the need for artificial lighting and improve energy efficiency.
Thermal and Acoustic Insulation:
- Modern framed-type glass curtain walls are designed to provide thermal insulation, helping to keep the building warm in the winter and cool in the summer. This is typically achieved through the use of double or triple glazing.
- These curtain wall systems also offer sound insulation, which is important in urban environments where noise pollution can be a concern.
Weather Protection:
- The joints between the glass panels and the frame are sealed to prevent water and air infiltration, ensuring that the interior of the building remains protected from the elements.
- Many curtain wall systems include drainage systems to manage any water that penetrates the outer seals, preventing it from reaching the interior.
[edit] Types of Framed-Type Glass Curtain Walls
- Stick system: The stick system involves assembling the curtain wall components (i.e., mullions and glass panels) on-site. This allows for flexibility and adjustments during installation but can be more time-consuming.
- Unitised system: In the unitized system, large units or modules of the curtain wall are pre-assembled in a factory. These units are then transported to the site and installed. This method is faster and often results in higher quality due to controlled factory conditions.
[edit] Applications
Framed-type glass curtain walls are commonly used in:
- Commercial buildings such as office buildings, shopping malls, and hotels.
- High-rise buildings where they provide a striking appearance and enhance natural lighting.
- Institutional buildings including hospitals, universities, and libraries, where aesthetic appeal and functionality are important.
[edit] Related articles on Designing Buildings
- Brick veneer.
- British post-war mass housing.
- Building fabric.
- Cladding.
- Curtain wall.
- Facade cleaning.
- Fire performance of external thermal insulation for walls of multistorey buildings, third edition (BR 135).
- Infill panel walls.
- Metal composite panels.
- Off-site prefabrication of buildings: A guide to connection choices.
- Patent glazing.
- Rainscreen.
- Sandwich panel.
- Structural glass assembly.
Featured articles and news
Costs and insolvencies mount for SMEs, despite growth
Construction sector under insolvency and wage bill pressure in part linked to National Insurance, says report.
The place for vitrified clay pipes in modern infrastructure
Why vitrified clay pipes are reclaiming their role in built projects.
Research by construction PR consultancy LMC published.
Roles and responsibilities of domestic clients
ACA Safety in Construction guide for domestic clients.
Fire door compliance in UK commercial buildings
Architect and manufacturer gives their low down.
Plumbing and heating for sustainability in new properties
Technical Engineer runs through changes in regulations, innovations in materials, and product systems.
Awareness of the Carbon Border Adjustment Mechanism
What CBAM is and what to do about it.
The new towns and strategic environmental assessments
12 locations of the New Towns Taskforce reduced to 7 within the new towns draft programme and open consultation.
Buildings that changed the future of architecture. Book review.
The Sustainability Pathfinder© Handbook
Built environment agency launches free Pathfinder© tool to help businesses progress sustainability strategies.
Government outcome to the late payment consultation, ECA reacts.
IHBC 2025 Gus Astley Student Award winners
Work on the role of hewing in UK historic conservation a win for Jack Parker of Oxford Brookes University.
Future Homes Building Standards and plug-in solar
Parts F and L amendments, the availability of solar panels and industry responses.
How later living housing can help solve the housing crisis
Unlocking homes, unlocking lives.
Preparing safety case reports for HRBs under the BSA
A new practical guide to preparing structural inputs for safety cases and safety case reports published by IStructE.
Male construction workers and prostate cancer
CIOB and Prostate Cancer UK encourage awareness of prostate cancer risks, and what to do about it.